Determination of Heat and Moisture Balance for Broiler House

Authors : Adil Akyuz and Sedat Boyaci

Abstract: The aim of this study was carried out to determine the heat and humidity balance for one of broiler houses as an example of the broiler house based on the traditional poultry production systems in Kahramanmaras, Turkey. In the first period in February and March, inside temperature of broiler house was lower than the optimal temperature whereas inside relative humidity of broiler house was close to the optimum relative humidity level. In the second period in August and September inside temperature of broiler house at 2nd week was close to the optimal temperature whereas the inside temperature of broiler house at 3-7 weeks was higher than the optimal temperature. On the other hand, inside relative humidity of broiler house at 3-7 weeks of second period was lower than the optimum relative humidity level. In the first period in February and March sensible heat dissipated by broiler was ranged from 1.20-4.50 kcal h-1, moisture from 1.30 -4.20 g h-1 and net heat output through the structural elements from 8.40-14.00 kcal m-2 °C. In the second period in August and September, Sensible heat dissipated by broiler was ranged from 0.80-4.50 kcal h-1, Moisture from 0.80-4.20 g h-1 and the net heat output through the structural elements from 1.10-3.80 kcalm-2°C. Although, there is need for supplementary heat during the first period in February and March there is no need for supplementary heat during the first period in August and September for poultry house in Kahramanmaras, Turkey.

How to cite this article:

Adil Akyuz and Sedat Boyaci, 2010. Determination of Heat and Moisture Balance for Broiler House. Journal of Animal and Veterinary Advances, 9: 1899-1901.

INTRODUCTION

Broiler chicken industry has continuously grown recently and is considered an important livestock sector in Turkey as in many countries (Atilgan and Koknaroglu, 2006). Although, the feed accounts for 70-80% of the production cost of poultry (Karaman et al., 2009), there are some other factors affecting the production cost of poultry such climatic conditions inside the poultry house. Heat, humidity ammonia and carbon dioxide in poultry house have a negative effect on broiler performance (Atilgan et al., 2010).

As in many developing countries, some of poultry population in Turkey is found in the traditional family based poultry production systems. In such production systems high ambient temperatures can be devastating to commercial broilers coupled with high humidity they can have an even more harmful effect. Heat stress interferes with the broilers comfort and suppresses productive efficiency.

During periods of heat stress the broiler has to make major thermo regulatory adaptations in order to prevent death from heat exhaustion (Butcher and Miles, 1996). The aim of this study was carried out to determine the heat and humidity balance for one of broiler houses as an example of the broiler house based on the traditional poultry production systems in Kahramanmaras, Turkey.

MATERIALS AND METHODS

This experiment was carried out in broiler house in Kahramanmaras Sutcu Imam University Experimental Farm, in Kahramanmaras, Turkey for two periods. First period lasted 5 weeks in February and March. Second period lasted 6 weeks in August and September. In the current experiment ROSS chicks were used. In this study, 4 humidity sensors and 12 temperature sensors were used in broiler house and 1 humidity sensor and 1 temperature sensor outside of broiler house.

The measurement of humidity and temperature of inside and outside of broiler house were carried out at three different time points of a day (7.00 am, 14.00 pm and 21.00 pm) using data logger with sensors. The means of daily temperature and humidity were estimated as follow:


The general heat balance for the broiler house was calculated as follow:

Where:

qd = Sensible heat dissipated by broiler (kcal h-1)
qh = Heat output through ventilation
qy = The net heat output through the structural elements (roof, wall, window, door)

Heat output through ventilation was calculated as follow:

Where:

Qh = Minimum ventilation discharge rate
ti = Inside temperature of house
td = Outside temperature of house

The net heat output through the structural elements was calculated as follow:

Where:

Uy = Heat transfer coefficient of structure
Ay = Surface area of structure
ti = Inside temperature of house
td = Outside temperature of house

The heat transfer coefficient of structure (Uy) was calculated as follow:

Where:

fi = Inside heat conductance
di = Thickness of structure
ki = Thermal conductivity of structure
fd = Outside heat conductance

The general moisture balance for the broiler house was calculated as follow:

Where:

Wh = Moisture released by poultry
G = Ventilation amount (kg h-1)
W1 = Absolute air moisture (g m-3) inside the house
W2 = Absolute air moisture (g m-3) outside the house

RESULTS AND DISCUSION

The temperature and humidity values of 5 weeks in the first period (in February and March) are shown in Fig. 1. Lindley and Whitaker (1996) indicated that optimum inside temperature of broiler house should be 32-33°C in 1-2 weeks and 21°C in 3-7 weeks. In the current experiment inside temperature of broiler house in February and March was lower than the optimal temperature.

Ekmekyapar indicated that optimum inside relative humidity of broiler house should be 40-70% in 1-2 weeks and 65-70 % in 3-7 weeks. In the current experiment inside relative humidity of broiler house was close to the optimum relative humidity level. The temperature and humidity values of 6 weeks in the second period (August and September) are shown in Fig. 2.

In the current experiment inside temperature of broiler house at 2nd week of second period was close to the optimal temperature whereas the inside temperature of broiler house at 3-7 weeks was higher than the optimal temperature. On the other hand, inside relative humidity of broiler house at 3-7 weeks of second period was lower than the optimum relative humidity level.

The general heat and moisture balance for the broiler house calculated in February and March was shown Table 1. Sensible heat dissipated by broiler was ranged from 1.20-4.50 kcal h-1 in February and March. Moisture released by poultry ranged from 1.30-4.20 g h-1 in February and March. The net heat output through the structural elements was ranged from 8.40-14.00 kcal m-2 °C in February and March.

Fig. 1(a, b): The temperature and humidity values of 5 weeks in the first period

Fig. 2(a, b): The temperature and humidity values of 6 weeks in the second period

Table 1: The general heat and moisture balance for the broiler house calculated in February and March
qd = sensible heat dissipated by broiler (kcal/h), Wh = moisture released by poultry (g/h), qy = the net heat output through the structural elements (kcal m-2 °C h),

Table 2: The general heat and moisture balance for the broiler house calculated in August and September

The general heat and moisture balance for the broiler house calculated in August and September was shown Table 2. Sensible heat dissipated by broiler was ranged from 0.80-4.50 kcal h-1. Moisture released by poultry ranged from 0.80-4.20 g h-1. The net heat output through the structural elements was ranged from 1.10-3.80 kcal m-2 °C.

CONCLUSION

Although, there is need for supplementary heat during the first period in February and March there is no need for supplementary heat during the first period in August and September for poultry house in Kahr aman- aras, Turkey.