Research Journal of Biological Sciences

Year: 2010
Volume: 5
Issue: 4
Page No. 289 - 292

Synthesis of Nano-Germanium Oxid/SBA-15 Composite for Extremely Sensitive Semiconductor Gas Sensor

Authors : Hossyn G. Bisheh and Akbar Rezayi

Abstract: An easy way has been practical to make nano-Germanium oxid (GeO2)/SBA-15 composites by damp impregnation of GeCl2 by means of SBA-15 as the nanoporous sensor support. Following integration SBA-15 with GeO2, the mesoporous array of SBA-15 could still be well upholder. The sensor prepared of the nano-GeO2/SBA-15 composite display advanced sensitivities and the sensitivity to 1000 ppm of H2 could be higher than 1300 which is almost 35 times extra sensitive than that of pure GeO2 sensor. This judgment provides an inexpensive and effectual method to apply nanoporous materials to outstandingly improve the sensitivity of semiconductor metal oxide gas sensors.

How to cite this article:

Hossyn G. Bisheh and Akbar Rezayi, 2010. Synthesis of Nano-Germanium Oxid/SBA-15 Composite for Extremely Sensitive Semiconductor Gas Sensor. Research Journal of Biological Sciences, 5: 289-292.

INTRODUCTION

From the time when the innovation of mesoporous silicates molecular strainer in 1992 (Kresge et al., 1992), nanobased mesoporous materials have paying considerable attention for the reason that of their exceedingly pre-arranged pore structure as well as high surface area. A number of revisions have been intended at amending mesoporous materials in order to amplify the possible applicability of these materials (Xia et al., 2000). Lately with the growth of semiconducting metal oxide gas sensors (Ashraf et al., 2007), more labors are focal point on the research of mesoporous silica materials to amplify the assets of metal oxide gas sensors.

Numerous trails have been reported and comprehensived to the synthesis of a diversity of mesoporous metal oxides for gas sensing subsequent the discovery of MCM family of mesoporous silicates by means of supramolecular templating approach (Ramgir et al., 2006), nevertheless, the majority of such mesoporous structured metal oxides were not steady after the elimination of surfactant and pore structure would fall down at high temperature (Michot et al., 1998). A new way was to mechanically mixing with mesoporous material (Guo et al., 2005) and the sensitivity of the mechanical mixture sensor to H2 was improved about 4 times compared with that of pure GeO2 gas sensor. Nevertheless, mechanical mixing could not give a uniform dispersal of sensor component on the support. In current research, an easy chemical mixing way has been practical to get organized homogeneous nanosized GeO2/SBA-15 composites. GeCl2 was chosen as the forerunner and SBA-15 as the nanoporous material. The sensors based on such composite illustrate much higher hydrogen sensitivity than those of pure GeO2 sensor and the sensor prepared from a mechanical mixture of GeO2 with SBA-15.

MATERIALS AND METHODS

Nanoporous SBA-15 material prepared as one literature procedure (Zhao et al., 1998). Pluronic 123 triblock polymer ((EO)20(PO)70 (EO)20, Aldrich) was used as the surfactant and tetraethyl orthosilicate (TEOS, 98%, Aldrich) as the silicon source. After hydrothermal treatment in acidic condition, the sample was dried and calcined at 550°C for 10 h to remove the surfactant. For the preparation of GeO2/SBA-15 composite, 0.3 g of GeCl2.2H2 O was dissolved in 20 mL of 0.2 N HCl solution. After stirring for 30 min, 0.3 g of SBA-15 was added to the solution and stirring was continued for another 6 h. The temperature was then raised to 100°C to remove water. Finally, the sample was calcined at 700°C in air for 4 h with a heating rate of 10°C min-1 to oxidize GeCl2-GeO2. The sample is referred as GeO2 (40% wt.)/SBA-15 where 40 wt% stands for the weight ratio of GeO2 in the mixture. Pure GeO2 in the absence of SBA-15 was synthesized using the same method. The N2 adsorption-desorption isotherms measurements were performed on quantachrome autosorb-1 analyzer. The XRD patterns were recorded on a SHIMADZU X-6000 X-ray diffractometer using Cu Ka radiation as the X-ray source (λ = 1.5418 Å) with a scan speed of 2° min-1. Sensors were fabricated by pressing the powder sample into pellet (10 mm in diameter and 1 mm in thickness) with 2 Pt wires embedded as electrodes. For Sensing test, the sensor was mounted into a specially designed quartz cell and the reducing gas used in this study was 1000 ppm of H2. The sensitivity of the sensor is uttered as the ratio of the resistance of the sensor in air to the resistance of the sensor in H2, i.e., S = Rair /RH2.

RESULTS AND DISCUSSION

Figure 1 shows the small angle XRD prototypes of unadulterated SBA-15 and GeO2 (40% wt.)/SBA-15 composite. GeO2 (40% wt.)/SBA-15 composite displays a very alike prototype as that of unadulterated SBA-15 with well resolved diffraction peaks which are indexed to the 100, 110 and 200 reflections of two-dimensional hexagonal mesostructure (Zhao et al., 1998). The consequences point to that the attribute hexagonal mesoporous features of SBA-15 are still well maintained in the GeO2 (40% wt.)/ SBA-15 sample after mixing and calcination. Even though the greatness of (100) diffraction peak has reduced in GeO2 (40% wt.)/SBA-15 composite, its 2θ angle is kept fairly constant.

The d-spacing which could be considered from the corresponding 2θ value does not budge, suggesting that the d100-spacing has not been affected by the incorporation with GeO2. The wide-angle XRD prototype of GeO2 (40 % wt.)/SBA-15 sample in Fig. 1 shows well-resolved diffraction peaks of the GeO2 nanocrystals which can be indexed to a tetragonal structure (Hu et al., 2002).

There is no new peak in the XRD spectra, representative that there is no new material formed. Furthermore, compared with the pure GeO2 crystals synthesized in the absence of SBA-15, GeO2/SBA-15 has broader XRD peaks. The broad nature of the XRD peaks of GeO2 (40 wt%)/SBA-15 show the attendance of very small crystallites of GeO2 on SBA-15. This result advocated that SBA-15 not only acts as a support but also restrains the crystallite growth during calcination (Xu et al., 2005).

Figure 2 shows the N2 adsorption-desorption isotherms of pure SBA-15 and GeO2 (40 wt%)/SBA-15 composite. GeO2 (40 % wt.)/SBA-15 shows the same type IV isotherms with H1 hysteresis loops which are typical for nanoporous materials with two-dimensional hexagonal structures, indicating that the mesoporous structure could be retained. The BET specific surface area of SBA-15 is 850 m2g-1 and that of GeO2 (40 % wt.)/SBA-15 composite reduces to 460 m2g-1.


Fig. 1: XRD prototype of (a) SBA-15 (b) GeO2 (40% wt.)/SBA-15 and (c) GeO2


Fig. 2: N2 adsorption-desorption isotherms and pore size allocation of (a) SBA-15 and (b) GeO2 (40% wt.)/SBA-15

For the meantime, the pore diameter decreases from 86-81 Å and total pore volume also decreases from 1.2-0.66 cm3g-1.

Since, the d100 spacing of SBA-15 has not been affected by mixing with GeO2, the decrease of pore diameter indicates that the pore wall became thicker, showing that some GeCl2 has entered into the mesopore of SBA-15 and nanocrystals of GeO2 have been shaped and entrenched on the internal surface of nanoporous SBA-15 support (Xu et al., 2005). Figure 3 shows the sensitivities of GeO2 (40% wt.)/SBA-15 composite sensor and pure GeO2 sensor to 1000 ppm of H2. The utmost sensitivity of pure GeO2 sensor to 1000 ppm of H2 is 35. However, the sensing properties of nano-GeO2 (40% wt.)/SBA-15 composite differ a lot. In fact, the GeO2 (40% wt.)/SBA-15 sensor exhibits a much improvement of sensitivity to H2, especially at 250°C where the sensitivity of the sensor to 1000 ppm of H2 reaches as high as 1400, almost 40 times higher than that of the pure GeO2 sensor.


Fig. 3: Sensing property of the sensor equipped from GeO2 with SBA-15

It should also be renowned that the most favorable sensing temperature of GeO2 (40% wt.)/SBA-15 sensor where the sensitivity is maximum is approximately 250°C which is lower than that of the pure GeO2 sensor (350°C). For comparison, a mechanical mixture of GeO2 with SBA-15 containing 40% wt. of GeO2 is also prepared following literature method (Guo et al., 2005) and the sensing property of the sensor equipped from the mechanical mixture of GeO2 with SBA-15 is shown in Fig. 3.

It could be obviously seen that the sensor equipped from nano-GeO2/SBA-15 composite possesses much higher sensitivity than that of the sensor equipped from the mechanical mixture of GeO2 with SBA-15. This outcome shows the significance of preparation methods in authority the property of gas sensors as the GeO2/SBA-15 composites sensor and the sensor equipped from the mechanical mixture of GeO2 with SBA-15 have the same components but dissimilar gas sensing properties. It is well known that the conductivity of GeO2 is mainly determined by the presence of singly charged oxygen vacancies.

When the reducing gas is introduced to the gas sensing system, it reacts with the surface oxygen ions and then the electrons are released to the semiconductor to increase the conductivity of the GeO2 sensor. Since, SBA-15 is known to be a good adsorbent for gases (Senguttuvan et al., 2006), GeO2/SBA-15 composite would be able to adsorb more oxygen or hydrogen and promote the reaction between hydrogen and the surface adsorbed oxygen hence, increasing the amount of released electrons and increasing the sensitivity of the composite sensor.

Furthermore, since the sensitivity of the sensor is determined by the competition between surface adsorption and surface reaction (Ramgir et al., 2006) and the adsorption of gases at lower temperature may be improved by the presence of mesoporous SBA-15, the optimum gas sensing temperature would shift to lower value.

Another probable motive for the improvement of the sensitivity of GeO2/SBA-15 could be accredited to the presence of GeO2 nanoparticles on GeO2/SBA-15 composite materials since, the reduction of crystal size can cause a huge development of gas sensitivity (Senguttuvan et al., 2006).

CONCLUSIONS

A lofty loading of nanocrystal GeO2 supported on nanoporous SBA-15 material has been synthesized by a easy chemical mixing way. These GeO2/SBA-15 composite gas sensors show extraordinarily improved sensitivities to reducing gases as contrast to that of the pure GeO2 gas sensor. The consequences show the huge potential of use a material with high BET surface area and homogeneous nanopore as a sensor support to improve the sensitivities of semiconductor metal oxide gas sensor for prospect sensing claim.

ACKNOWLEDGEMENT

The researchers acknowledge financial support from Islamic Azad University at Ghaemshahr Branch.

Design and power by Medwell Web Development Team. © Medwell Publishing 2024 All Rights Reserved