Journal of Engineering and Applied Sciences

Year: 2016
Volume: 11
Issue: 12
Page No. 2688 - 2692

Design and Analysis of MEMS High Sensitive Capacitive Pressure Sensor

Authors : Muslihah Ali, Norhayati Soin, Abdullah C.W. Noorakma, Norliana Yusof and S.F. Wan Muhamad Hatta

References

Arsalan, M., M.H. Ouda, L. Marnat, T.J. Ahmad and A. Shamim et al., 2013. A 5.2 GHz, 0.5 mW RF powered wireless sensor with dual on-chip antennas for implantable intraocular pressure monitoring. Proceedings of the 2013 IEEE MTT-S International Conference on Microwave Symposium Digest (IMS), June 2-7, 2013, IEEE, Thuwal, Saudi Arabia, ISBN:978-1-4673-6176-7, pp: 1-4.

Ganji, B.A. and S.M. Tabarestani, 2013. A novel high sensitive MEMS intraocular capacitive pressure sensor. Microsyst. Technol., 19: 187-194.
CrossRef  |  Direct Link  |  

Katuri, K.C., S. Asrani and M.K. Ramasubramanian, 2008. Intraocular pressure monitoring sensors. IEEE. Sens. J., 8: 12-19.
CrossRef  |  Direct Link  |  

Kirstein, E.M., A. Elsheikh and P. Gunvant, 2011. Tonometry-Past, Present and Future. In: Glaucoma-Current Clinical and Research Aspects, Kirstein, E.M., A. Elsheikh and P. Gunvant (Eds.). In Tech Open Access Publisher, Pomona, California, ISBN:978-953-307-263-0, Pages: 388.

Latha, Y.M.A. and G. Khanna, 2015. Design and simulative analysis of a batteryless Teflon coated capacitive pressure sensor for glaucoma diagnosis. Proceedings of the 19th International Symposium on VLSI Design and Test (VDAT), June 26-29, 2015, IEEE, Hamirpur, India, ISBN:978-1-4799-1743-3, pp: 1-5.

Meng, E., P.J. Chen, D. Rodger, Y.C. Tai and M. Humayun, 2005. Implantable parylene MEMS for glaucoma therapy. Proceedings of the 2005 3rd IEEE-EMBS Special Topic Conference on Microtechnology in Medicine and Biology, May 12-15, 2005, IEEE, Los Angeles, California, USA., ISBN:0-7803-8711-2, pp: 116-119.

Moraes, C.G.V.D., T.S. Prata, J. Liebmann and R. Ritch, 2008. Modalities of tonometry and their accuracy with respect to corneal thickness and irregularities. J. Optometry, 1: 43-49.
Direct Link  |  

Nava, R.A. and L.N.D. Rivera, 2006. Intraocular pressure sensor design. Proceedings of the 2006 3rd International Conference on Electrical and Electronics Engineering, September 6-8, 2006, IEEE, Mexico City, Mexico, ISBN:1-4244-0402-9, pp: 1-4.

Smedt, D.S., 2015. Noninvasive intraocular pressure monitoring: Current insights. Clin. Ophthalmol., 9: 1385-1392.
CrossRef  |  

Tabarestani, S.M., B.A. Ganji and S.R. Nadooshan, 2012. Design and simulation of high sensitive capacitive pressure sensor with slotted diaphragm. Proceedings of the International Conference on Biomedical Engineering (IcoBE), February 27-28, 2012, IEEE, Tehran, Iran, ISBN:978-1-4577-1990-5, pp: 484-489.

Timoshenko, S. and S. Woinowsky-Krieger, 1959. Theory of Plates and Shells. 2nd Edn., McGraw-Hill Book Co., New York, pp: 580.

Design and power by Medwell Web Development Team. © Medwell Publishing 2024 All Rights Reserved