Journal of Engineering and Applied Sciences

Year: 2018
Volume: 13
Issue: 7
Page No. 1718 - 1724

FEM and Experimental Analysis of a Total Knee Prosthesis

Authors : Donatella Cerniglia, Tommaso Ingrassia, Vincenzo Nigrelli and Vito Ricotta

References

Arone, M., D. Cerniglia and V. Nigrelli, 2006. Defect characterization in Al welded joints by non-contact Lamb wave technique. J. Mater. Process. Technol., 176: 95-101.
CrossRef  |  Direct Link  |  

Bellemans, J., 1999. Osseointegration in porous coated knee arthroplasty: The influence of component coating type in sheep. Acta Orthopaedica Scand., 70: 1-35.
CrossRef  |  PubMed  |  Direct Link  |  

Cerniglia, D., N. Montinaro and V. Nigrelli, 2008. Detection of disbonds in multi-layer structures by laser-based ultrasonic technique. J. Adhes., 84: 811-829.
Direct Link  |  

Cerniglia, D., T. Ingrassia, L. D'Acquisto, M. Saporito and D. Tumino, 2012. Contact between the components of a knee prosthesis: Numerical and experimental study. Frattura ed Integrità Strutturale, 22: 56-68.
CrossRef  |  Direct Link  |  

Chen, F., G.M. Brown and M. Song, 2000. Overview of 3-D shape measurement using optical methods. Opt. Eng., 39: 10-23.
CrossRef  |  Direct Link  |  

Chiesa, R., M.C. Tanzi, S. Alfonsi, L. Paracchini and M. Moscatelli et al., 2000. Enhanced wear performance of highly crosslinked UHMWPE for artificial joints. J. Biomed. Mater. Res., 50: 381-387.
PubMed  |  Direct Link  |  

Godest, A.C., M. Beaugonin, E. Haug, M. Taylor and P.J. Gregson, 2002. Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. J. Biomech., 35: 267-275.
CrossRef  |  Direct Link  |  

Harris, M.L., P. Morberg, W.J.M. Bruce and W.R. Walsh, 1999. An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: A comparison of K-scan sensor and Fuji film. J. Biomech., 32: 951-958.
CrossRef  |  PubMed  |  Direct Link  |  

Ingrassia, T. and A. Mancuso, 2013. Virtual prototyping of a new intramedullary nail for tibial fractures. Intl. J. Interact. Des. Manuf., 7: 159-169.
Direct Link  |  

Ingrassia, T., A. Mancuso, V. Nigrelli and D. Tumino, 2014. Numerical study of the components positioning influence on the stability of a reverse shoulder prosthesis. Intl. J. Interact. Des. Manuf., 8: 187-197.
Direct Link  |  

Krautkramer, J. and H. Krautkramer, 2013. Ultrasonic Testing of Materials. 3rd Edn., Springer, Berlin, Germany, ISBN:978-3-662-02359-4, Pages: 667.

Liau, J.J., C.C. Hu, C.K. Cheng, C.H. Huang and W.H. Lo, 2001. The influence of inserting a Fuji pressure sensitive film between the tibiofemoral joint of knee prosthesis on actual contact characteristics. Clin. Biomech., 16: 160-166.
CrossRef  |  PubMed  |  Direct Link  |  

Morrison, J.B., 1970. The mechanics of the knee joint in relation to normal walking. J. Biomech., 3: 51-61.
CrossRef  |  PubMed  |  Direct Link  |  

Simo, J.C. and T.A. Laursen, 1992. An augmented Lagrangian treatment of contact problems involving friction. Comput. Struct., 42: 97-116.
CrossRef  |  Direct Link  |  

Design and power by Medwell Web Development Team. © Medwell Publishing 2024 All Rights Reserved