Novel Zero Voltage Transition (ZVT) Technique Based Closed Loop Control of Boost Power Factor Correction (PFC) Converter with EMI Filter

Authors : P. Ram Mohan , M. Vijaya Kumar , S. Rama Reddy and O.V. Raghava Reddy

Abstract: A novel Zero Voltage Transition (ZVT) technique based closed loop control of Boost Power Factor Correction (PFC) converter with Electro Magnetic Interference (EMI) Filter is presented in this paper. It operates at a fixed frequency while achieving zero voltage turn-on of the main switch and zero current turn-off of the boost diode. This is accomplished by employing resonant operation only during switch transitions. During the rest of the cycle, the resonant network is essentially removed from the circuit and converter operation is identical to its non-resonant counterpart. A prototype of 500W is built to test the proposed topology. The input voltage is from 170 to 230 Vrms. The output voltage is 400V. The operation frequency is 100 KHz. This technique increases the efficiency to 95% and power factor to 0.99.